Icold – Cold Room

ICold, an Elanpro group company, specializes in high-precision cold storage solutions essential for diverse industries. With expertise in temperature, humidity, and airflow control, ICold delivers custom-designed cold rooms tailored to specific requirements. Backed by advanced heat load calculations and globally recognized software,ICold ensures reliable, efficient, and accurate cold storage performance, making it a trusted name in the industry.

 

SKU Icold - Cold Room Category

Technical Specifications

Icold solutions cover various Industries like:

Agriculture
Dairy
Floriculture
Food Processing
Horticulture
Meat Processing
Ripening Chambers
Sea food
Ice Cream
Industrial Canteens
Hotels & Restaurants
R&D Laboratories
Pharmaceuticals
Healthcare

Key Features:

Panels

  • Modular Design: Interlocking panels for customizable cold room sizes.
  • Versatile Application: Suitable for small walk-ins to large cold stores.
  • Flexible Options: Available in various profiles, thicknesses, and finishes.
  • Easy Installation: Pre-fabricated panels for quick on-site assembly.

Doors

  • Self-Closing: Closes automatically without human effort.
  • Safety Release: Can be opened from the inside for safety.
  • View Port: Allows product visibility without opening the door, saving energy.
  • Posi Seal: Ensures perfect alignment and closing.
  • Sweep Gasket: Airtight seal remains flexible at any temperature.
  • Thermal Break: Prevents condensation and ice buil-up

 

Key Specifications

Sno. Description Specifications
1 PUF Panel Thickness 60/80/100/125/150 mm
2 PUF Panel Cover PP or SS
3 Sheet Metal Thickness 0.4/0.5 mm
4 Temperature Range -400°C to 800°C
5 PUF Blowing Agent Cyclopentane – (CFC & HCFC free)
6 Lock Arrangement Cam-Lock with metal locking devise
7 PUF Density 40Kg/m3 ±2Kg/m3
8 K- value (w/m OK) 0.021 – 0.023
9 Panel Length Upto 11.5m
10 Panel Width 5.75/11.5/23/34.5/46 inches 146/292/584 /876/1168 mm
11 Panel Joint Tongue & Groove joint
12 Panel to Panel Fitment The gap between two fitted panels < 3 mm
13 PIR Fire retarded panels

Microprocessor Controller and Power Panel

Icold cooling solutions feature intelligent microprocessor controllers that are BMS compatible and
HACCP-provided (in select models). Each refrigeration unit includes ready-to-use power panels for quick,
safe, and durable electrical connections. These power panels come with powder-coated weatherproof
housing, protection against common electrical failures, and built-in safety interlocks.

Icold – Wide Range of Refrigeration Units

Versatile Cooling Solutions: Wide range of evaporating and condensing units, including air-cooled and
water-

cooled condensers, designed for multiple temperature zones: Low (-23°C to -5°C), Medium (-5°C to +20°C),
High

(+20°C to +15°C), and Blast Freezing (-35°C to -40°C).

Superior Build Quality

Stainless steel body for corrosion resistance, inner grooved copper tubes for efficient heat transfer,
and in-built defrost heaters for low-temperature units.

User-Friendly Design

Low-noise external rotor fans and removable side panels for easy maintenance and servicing.

Accessories

Floor
Finishes

Optional
Accessories

 

FOR HIGHER TEMPERATURE @ 2 to 6 Deg C
Refrigeration Model
No.
Refrigeration
Capacity KW
Refrigerant Temp. Range (c) Loading Temp.(C) Max. Loading (kgs/Day) Ambient (C) Power* Consumption (kw) Power Supply (V / Ph/Hz) Defrosting
CH-8 2.34 Kw R-134a 2 to 6 30-35 250 40 to 43 1.6 220V/1Ph/50Hz Air Off-cycle
CH-12 3.51 kw R-407c 2 to 6 30-35 540 38 to 42 1.9 220V/1ph/50Hz Air Off-cycle
CH-15 4.39 Kw R-407c 2 to 6 30-35 770 38 to 42 2.4 220V/1ph/50Hz Air Off-cycle
CH-19 5.85 Kw R-407c 2 to 6 30-35 1000 38 to 42 3.4 400V/3ph/50Hz Air Off-cycle
CH-21 6.14 Kw R-407c 2 to 6 30-35 1200 38 to 42 3.4 400V/3ph/50Hz Air Off-cycle
CH-42 12.29 Kw R-407c 2 to 6 30-35 2500 38 to 42 5.3 400V/3ph/50Hz Air Off-cycle
FOR LOW TEMPERATURE @ -16°C to -20°C
CL-4 1.17 kw R-404a -16 to -20 -10 to-15 100 38 to 42 1.5 220V/1ph/50Hz Electric
CL-6 1.17 kw R-404a -16 to -20 -10 to-15 200 38 to 42 2.0 400V/3ph/50Hz Electric
CL-8 2.34 Kw R-404a -16 to -20 -10 to-15 350 38 to 42 2.8 400V/3ph/50Hz Electric
CL-10 2.93 kw R-404a -16 to -20 -10 to-15 500 38 to 42 3.4 400V/3ph/50Hz Electric
CL-14 4.1 kw R-404a -16 to -20 -10 to-15 1000 38 to 42 4.3 400V/3ph/50Hz Electric

Basic of Design:

  1. Loading considered 50 kgs/sq. mts for Chiller and 30 kgs/sq. mts for Freezer room.
  2. Door Opening : 5 to 6 times /hrs
  3. Environment Friendly Refrigerant used Only

Note:
Data is at standard rating and it may vary according to application/site/ambient conditions.
Specification/data is subjected to change without prior notice.
Low temperature unit are available in option of Hermetic/Bitzer Semi-Hermetic as per customer requirement.

unlock your download by completing the form

unlock your download by completing the form

unlock your download by completing the form

unlock your download by completing the form

unlock your download by completing the form

unlock your download by completing the form

unlock your download by completing the form

unlock your download by completing the form

unlock your download by completing the form

unlock your download by completing the form

unlock your download by completing the form

unlock your download by completing the form

unlock your download by completing the form